CHAPTER 11 A PICTORIAL EXAMPLE

11.4

Sensitivity Specifications

11.4.1

A Log Sensitivity Specification

We consider the plant perturbation

std

0 ( ) =

std

0 ( )

P

s

P

s

, a gain variation in std

0 (see section 9.1.3). Figure 11.13 shows the level curves of

i.e.

P

the maximum logarithmic sensitivity of the magnitude of the I/O transfer function

13, over the frequency range 0

1, to these gain changes, ,

H

!

i.e.

sup @

log

) = max

( )

(11.12)

0

1

13(

=0

jH

j

!

j

0

1 j<S j! j

!

@

!

where

( ) = 1

(a)

(b)

(c)

13 ( ) +

13 ( ) + (1

) 13 ( )

S

j

!

;

H

j

!

H

j

!

;

;

H

j

!

:

As expected, the level curves in gure 11.13 bound convex subsets of slice.

H

2

0:8

0:7

0:6

0:5

0:4

1:5

0:3

0:2

0:1

1

0:5

0:4

0

0:5

0:6

;0:5

0:7

0:8

;1

;1

;0:5

0

0:5

1

1:5

2

Level curves of the logarithmic sensitivity of the magnitude

Figure

11.13

of the I/O transfer function

, over the frequency range 0

1, to

H

!

13

gain changes in the plant

, given by (11.12).

std

P

0

When the function (11.12) takes on the value 0.3, the maximum rst order

change in 13( ) , over 0

1, with a 25% plant gain change is exp(0 075),

jH

j

!

j

!

:

or 0 65dB. In gure 11.14 the actual maximum change in 13( ) is shown for

:

jH

j

!

j

points on the 0 3 contour of the function (11.12).

:

index-270_1.png

index-270_2.png

index-270_3.png

index-270_4.png

index-270_5.png

index-270_6.png

index-270_7.png

11.4 SENSITIVITY SPECIFICATIONS

261

2

q

0 85dB

:

0 63dB

:

q

1:5

0 58dB

:

q

0 55dB

:

q

1

0 53dB

:

q

0:5

0 63dB

:

q

0 51dB

:

0 54dB

q

0

0 35dB

:

q

:

q

0 39dB

:

q

;0:5

0 57dB

:

q

;1

;1

;0:5

0

0:5

1

1:5

2

To rst order, the peak change in 13( ) for 0

1

Figure

11.14

jH

j

!

j

!

along the 0.3 contour in gure 11.13, for a 25% gain change in std

0 , will be

P

0 65dB. The 0.3 contour from gure 11.13 is shown, together with the actual

:

peak change in 13( ) for 0

1 for several points on the contour.

jH

j

!

j

!

11.4.2

A Step Response Sensitivity Specification

In section 9.3 we considered the sensitivity of the I/O step response at t = 1 to

plant gain changes, i.e., Pstd

0 = Pstd

0 :

s (1) = @s(1)

@

:

=0

Figure 11.15 shows the subset of slice for which

H

s (1) 0:75:

j

j

This speci cation is equivalent to

1 Z 1 (1 T(j!))T(j!)

;

2

j!

ej! d! 0:75

(11.13)

;1

where

T(j!) = H(a)

13 (j!) + H(b)

13 (j!) + (1

)H(c)

13 (j!):

;

;

As we showed in section 9.3, and as is clear from gure 11.15, the step response

sensitivity speci cation (11.13) is not convex.

index-271_1.png

index-271_2.png

index-271_3.png

index-271_4.png

index-271_5.png

index-271_6.png

index-271_7.png

index-271_8.png

index-271_9.png

262

Find Your Next Great Read

Describe what you're looking for in as much detail as you'd like.
Our AI reads your request and finds the best matching books for you.

Showing results for ""

Popular searches:

Romance Mystery & Thriller Self-Help Sci-Fi Business